Obtaining amassed treasured knowledge in cooperating with foreign clients, Keeping in brain that good support is the essential to cooperating with clients, we strive to satisfy higher quality requirements, provide aggressive prices and guarantee prompt supply. Due to our sincerity in offering ideal service to our customers, comprehension of your needs and overriding perception of obligation toward filling purchasing specifications,
knowledge sheet :
Design | GDP20*S | ||
Section | 3 Phase | ||
EPTT Issue | .8cos Oslash | ||
Frequency | 50HZ | ||
Velocity | RPM | 1500 | |
Max. EPTT | KVA | 22 | |
KW | 17.6 | ||
Rated EPTT | KVA | 20 | |
KW | sixteen | ||
Rated Voltage | V | 400 | |
Rated Current | A | 28 | |
Fuel Usage | L/H | four.6 | |
Generator EPTTler | JCEP Multi-function | ||
Engine Model. | 404A-22G/404D-22G | ||
Alternator Model. | JDG184E | ||
ClinEPTTNo. | 4/L | ||
Beginning Program | JCEP Commence | ||
Cooling Technique | JCEP-cooling | ||
Security Grade | IP23 | ||
Insulation Course | H | ||
Dimension (MM) | Silent Sort | 2100*740*1115 | |
Open up Sort | 1611*560*1191 | ||
Optional | ATS (automobile transfer swap) |
GODLIKE EPTT sort gensets
GODLIKE EPTT offers a broader selection of gensets, as effectively as other types of EPT
products and services.
uuml Gensets: one-stage and a few-phase turbines, manually operated or with
computerized (AMF) operation, stationary or cellular, installed outdoors – with
soundproof canopy, or indoors – open up frame versions, covering a EPTT selection
in between 10 and 2000kVA.
uuml The GODLIKE EPTT genset sequence has been created to satisfy all the energetic
necessities of every single variety of electric EPT, possessing a compact style, EPTTful,
reliable, easy to use and with silent procedure.
uuml GODLIKE EPTT gensets are equipped with diesel engines from renowned genset engines companies.
Inner combustion engine – Godlike EPTT gensets are geared up with
ideal high quality, globe extensive renowned engines.
The engines equipping the JDG sequence are reliable, minimal-noise,
EPTTful, with lower fuel consumption and produced making use of modern
technologies.
four stroke, water-cooled, direct EPT, in-line 2-six cylinders, in a natural way aspirated or turbocharged EPTT engines.
EPT or digital governor.
JCEP starter motor 12/24V DC.
Battery charging alternator twelve/24V DC.
Gas pump and fuel filter(s), oil pump and oil filter(s), gasoline EPT
pump, air filter(s).
Oil strain sensors, engine temperature sensors.
EPTT motor shutdown in situation of genset malfunction.
Pre-heating technique (only for automated gensets).
Exhaust program with reduced-noise muffler(s) and EPTow(s).
GENERATOR – EPT, four pole, one bearing or double bearing , brushless.
Self excited and self regulated by AVR (EPTT Voltage Regulator).
IP23 security degree.
Insulation course H.
SKID (Base Body)
The motor-generator assembly is manufactured by coupling the two main
factors by way of the SAE coupling technique. Many thanks to the EPTT anti-
vibration rubber damper pads, the genset does not induce apparent
vibrations to the encompassing foundation. The maXiHu (West EPT) Dis.mum vibration degree
induced to the genset foundation body is 5mm/s.
Gasoline TANK , is incorporated in the genset’s foundation body. As genset
manufacturer, GODLIKE EPTT can adapt to the customers’ requests by enlarging
or minimizing the fuel tank capacity, in purchase to guarantee the requested genset
autonomy. In addition, the gensets can be geared up with massive capacity
auXiHu (West EPT) Dis.liary (exterior) gas tanks with automated refueling method.
SOUNDPROOF Canopy , created from electrostatic spray-
painted metal sheet, which decreases the corrosive motion of atmospheric
and bordering environmental brokers.
EXEPTUST MUFFLER , assures silent genset operation and
minimizes the environmental effect of exhaust gas according to the
related EU stXiHu (West EPT) Dis.Hu (West EPT) Dis.rds.
COMMAND AND Handle PANEL
The manage panel is incEPTTd in the genset assembly, fitted on the
genset’s foundation frame and can be visualized through a single of the canopy
door’s pleXiHu (West EPT) Dis.glas window.
The gensets are geared up with manually operated or computerized
procedure electric panels, in accordance to the customer’s request.
The panels offer you numerous set-up and safety features and operating
modes. The gensets can also be distant operated and monitored using
the Computer, incXiHu (West EPT) Dis.Hu (West EPT) Dis. through World wide web and GEPT, as an optional extra. The
management panel is friendly and easy to use. The automated manage panels
can be manufactures as a twin EPT board (the control-side
apparatus is separated from the switchEPT).
Good quality STHangEPTRDS
The GODLIKE EPTT sequence gensets are made and created by our
business in accordance with the most recent issued CE!
Item No |
Genset Product | EPTT Out Set 400V/50HZ/1500RPM/3P/.eight ( Y ) |
Perkins Engine Product |
Godlike Alternator Design |
|
EPT forty degree | |||||
one | GDP9 | 7KW | 9KVA | 403A-11G | JDG 164B |
two | GDP9 | 7KW | 9KVA | 403D-11G | JDG 164B |
3 | GDP13 | 10KW | 13KVA | 403A-15G1 | JDG 164C |
4 | GDP13 | 10KW | 13KVA | 403D-15G | JDG 164C |
5 | GDP15 | 12KW | 15KVA | 403A-15G2 | JDG 164D |
6 | GDP20 | 16KW | 20KVA | 404A-22G | JDG 184E |
seven | GDP20 | 16KW | 20KVA | 404D-22G | JDG 184E |
eight | GDP27 | 21KW | 27KVA | 404D-22TG | JDG 184F |
9 | GDP30 | 24KW | 30KVA | 1103A-33G | JDG 184G |
10 | GDP30 | 24KW | 30KVA | 1103A-33G | JDG 184G |
eleven | GDP45 | 36KW | 45KVA | 1103A-33TG1 | JDG 224C |
twelve | GDP45 | 36KW | 45KVA | 1103A-33TG1 | JDG 224C |
thirteen | GDP60 | 48KW | 60KVA | 1103A-33TG2 | JDG 224E |
14 | GDP60 | 48KW | 60KVA | 1103A-33TG2 | JDG 224E |
15 | GDP65 | 52KW | 65KVA | 1104A-44TG1 | JDG 224E |
sixteen | GDP80 | 64KW | 80KVA | 1104A-44TG2 | JDG 224GS |
seventeen | GDP80 | 64KW | 80KVA | 1104C-44TAG1 | JDG 224GS |
eighteen | GDP90 | 72KW | 90KVA | 1104C-44TAG2 | JDG 274H |
19 | GDP100 | 80KW | 100KVA | 1104C-44TAG2 | JDG 274C |
20 | GDP100 | 80KW | 100KVA | 1006TG2A | JDG 274C |
21 | GDP135 | 108KW | 135KVA | 1006TAG | JDG 274ES |
22 | GDP150 | 120KW | 150KVA | 1006TAG2 | JDG 274E |
23 | GDP150 | 120KW | 150KVA | 1106A-70TAG2 | JDG 274E |
24 | GDP181 | 145KW | 181KVA | 1106A-70TAG3 | JDG 274G |
twenty five | GDP200 | 160KW | 200KVA | 1106A-70TAG4 | JDG 274H |
26 | GDP208 | 166KW | 208KVA | 1306C-E87TAG3 | JDG 274H |
27 | GDP225 | 180KW | 225KVA | 1306C-E87TAG4 | JDG 274J |
28 | GDP250 | 200KW | 250KVA | 1306C-E87TAG6 | JDG 274K |
29 | GDP275 | 220KW | 275KVA | 1606A-E93TAG4 | JDG 314DS |
30 | GDP300 | 240KW | 300KVA | 1606A-E93TAG5 | JDG 314D |
31 | GDP350 | 280KW | 350KVA | 2206C-E13TAG2 | JDG 314E |
32 | GDP375 | 300KW | 375KVA | 2206C-E13TAG3 | JDG314FS |
33 | GDP400 | 320KW | 400KVA | 2206C-E13TAG3 | JDG 314F |
34 | GDP455 | 364KW | 455KVA | 2506C-E15TAG1 | JDG 354C |
35 | GDP500 | 400KW | 500KVA | 2506C-E15TAG2 | JDG 354D |
36 | GDP600 | 480KW | 600KVA | 2806C-E18TAG1A | JDG 354E |
37 | GDP625 | 500KW | 625KVA | 2806A-E18TAG2 | JDG354FS |
38 | GDP650 | 520KW | 650KVA | 2806A-E18TAG2 | JDG354F |
39 | GDP750 | 600KW | 750KVA | 4006-23TAG2A | JDG404B |
forty | GDP800 | 640KW | 800KVA | 4006-23TAG3A | JDG404C |
41 | GDP900 | 720KW | 900KVA | 4008TAG1A | JDG404D |
forty two | GDP1571 | 818KW | 1571KVA | 4008TAG2A | JDG404E |
43 | GDP1250 | 1000KW | 1250KVA | 4012-46TWG2A | JDG404G |